Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Journal of Experimental Hematology ; (6): 850-854, 2023.
Artículo en Chino | WPRIM | ID: wpr-982140

RESUMEN

OBJECTIVE@#To investigate the causes of ineffectiveness of platelet transfusion with monoclonal antibody solid phase platelet antibody test (MASPAT) matching in patients with allogeneic hematopoietic stem cell transplantation and explore the strategies of platelet transfusion.@*METHODS@#A case of donor-specific HLA antibodies (DSA) induced by transfusion which ultimately resulted in transplantation failure and ineffective platelet transfusion with MASPAT matching was selected, and the causes of ineffective platelet transfusion and platelet transfusion strategy were retrospectively analyzed.@*RESULTS@#The 32-year-old female patient was diagnosed as acute myeloid leukemia (high risk) in another hospital with the main symptoms of fever and leukopenia, who should be admitted for hematopoietic stem cell transplantation after remission by chemotherapy. In the course of chemotherapy, DSA was generated due to platelet transfusion, and had HLA gene loci incompatible with the donor of the first transplant, leading to the failure of the first transplant. The patient received platelet transfusion for several times before and after transplantation, and the results showed that the effective rate of MASPAT matched platelet transfusion was only 35.3%. Further analysis showed that the reason for the ineffective platelet transfusion was due to the missed detection of antibodies by MASPAT method. During the second hematopoietic stem cell transplantation, the DSA-negative donor was selected, and the matching platelets but ineffective transfusion during the primary transplantation were avoided. Finally, the patient was successfully transplanted and discharged from hospital.@*CONCLUSIONS@#DSA can cause graft failure or render the graft ineffective. For the platelet transfusion of patients with DSA, the platelet transfusion strategy with matching type only using MASPAT method will miss the detection of antibodies, resulting in invalid platelet transfusion.


Asunto(s)
Femenino , Humanos , Adulto , Transfusión de Plaquetas , Anticuerpos Monoclonales , Estudios Retrospectivos , Antígenos HLA , Trasplante de Células Madre Hematopoyéticas
2.
Journal of Experimental Hematology ; (6): 503-508, 2023.
Artículo en Chino | WPRIM | ID: wpr-982087

RESUMEN

OBJECTIVE@#To establish the diagnostic process of low titer blood group antibody in the occurrence of adverse reactions of hemolytic transfusion.@*METHODS@#Acid elusion test, enzyme method and PEG method were used for antibody identification. Combined with the patient's clinical symptoms and relevant inspection indexes, the irregular antibodies leading to hemolysis were detected.@*RESULTS@#The patient's irregular antibody screening was positive, and it was determined that there was anti-Lea antibody in the serum. After the transfusion reaction, the low titer anti-E antibody was detected by enhanced test. The patient's Rh typing was Ccee, while the transfused red blood cells were ccEE. The new and old samples of the patient were matched with the transfused red blood cells by PEG method, and the major were incompatible. The evidence of hemolytic transfusion reaction was found.@*CONCLUSION@#Antibodies with low titer in serum are not easy to be detected, which often lead to severe hemolytic transfusion reaction.


Asunto(s)
Humanos , Transfusión Sanguínea , Reacción a la Transfusión/prevención & control , Hemólisis , Antígenos de Grupos Sanguíneos , Transfusión de Eritrocitos , Anticuerpos , Isoanticuerpos , Incompatibilidad de Grupos Sanguíneos
3.
Journal of Experimental Hematology ; (6): 1478-1482, 2015.
Artículo en Chino | WPRIM | ID: wpr-274012

RESUMEN

<p><b>OBJECTIVE</b>To evaluate the effects of the 25 Gy ⁶⁰Co irradiation on the physiological and biochemical properties and the functions of the platelets during storage.</p><p><b>METHODS</b>A total of 15 bags of platelets were apheresis-collected from 15 healthy donors, and each bag of platelets were divided into 2 parts, then the platelets were divided into the control group (without 25 Gy ⁶⁰Co irradiation) and the irradiated group (with 25 Gy ⁶⁰Co irradiation) groups. The two groups of platelets were kept under the condition of (22 ± 2) °C and shaken. The Platelet count and pH value were detected on the d 1, d 2, d 3, d 4 and d 5. The variables such as R, K values, α angle and maximal amplitude (MA) were measured by thrombelastography on the same days. Hypotonic shock response (HSR), morphological score were devised.</p><p><b>RESULTS</b>There were no statistically significant difference in Plt counts, mean platelet volume (MPV), platelet distribute width (PDW) and pH between the two groups (P > 0.05), and Plt count decreased on the end of storage. There were no marked changes in HSR level and morphological score between the two groups during storage, and there were no significant difference between the two groups (P > 0.05). In the TEG analysis there were no significant difference of the R, K, α angle and MA values between the two groups (P > 0.05). R value showed upward trend increased along with prolongation of preserved time (P < 0.01), no significant changes in α angle (P > 0.05), K value was slightly higher and MA value was lower in the last day of storage than the days 1-4 (P < 0.01), respectively.</p><p><b>CONCLUSION</b>25 Gy ⁶⁰Co gamma-ray irradiation can not damage the physiological, biochemical properties and the functions of the platelets during storage. In order to ensure the best curative effect, it is suggested that no matter the platelets were irradiated or not, the platelets should be used as soon as possible.</p>


Asunto(s)
Humanos , Plaquetas , Efectos de la Radiación , Conservación de la Sangre , Rayos gamma , Recuento de Plaquetas
4.
Journal of Experimental Hematology ; (6): 1363-1367, 2009.
Artículo en Chino | WPRIM | ID: wpr-343284

RESUMEN

This study was aimed to establish a genotyping method to detect ABO group gene of fetus from peripheral blood of pregnant women for prenatal diagnosis of hemolytic disease of newborn (HDN) resulting from ABO blood group incompatibility. 4 pairs of primers were designed according to ABO blood group gene DNA and mRNA sequences. 20 plasma DNA samples from healthy donors were extracted and amplified to explore the best conditions for plasma DNA extraction and PCR amplification. The O group plasma DNA was mixed with A group or B group plasmas by the ratios of 1:1, 2:1, 4:1, 8:1, 10:1, 20:1, 40:1, 100:1 to simulate the status of mixed ABO gene from pregnant maternal blood and to establish the mixed blood group ABO genotyping technology. The pregnant maternal blood samples with more than 30 weeks of gestation were selected for detecting the fetal ABO blood group genotype. The blood samples should be taken as possible as after birth for identification of ABO blood group and evaluation of sensitivity and accuracy of fetal ABO blood group genotyping technology through peripheral blood of pregnant women. The results indicated that the minimal amount of template DNA from single blood plasma for accuracy identification was at least about 0.625 ng, the DNA amount extracted from 500 microl of plasma could meet the requirement for PCR amplification. When the proportion of O group plasma DNA in mixed plasma DNA was <or=10, the non-O group gene could be accurately detected. Among 14 peripheral blood samples from O-group pregnant women, the non-O group gene was amplified in 9 samples; the non-O group gene was not amplified in 5 samples. The identification of peripheral blood ABO group for 5 newborns using serologic method showed that the A group 3 cases, B group 2 cases, O group 1 case, which consisted with genotyping results with consistent rate 100%. It is concluded that in middle and late pregnancy the fetal ABO group gene can be detected accurately by means of established fetal ABO group gene extraction and typing technology, that provides some guidances for the prenatal diagnosis and prevention of HDN.


Asunto(s)
Femenino , Humanos , Embarazo , Sistema del Grupo Sanguíneo ABO , Genética , Alergia e Inmunología , Antígenos de Grupos Sanguíneos , Sangre , Genética , Tipificación y Pruebas Cruzadas Sanguíneas , Métodos , Feto , Alergia e Inmunología , Genotipo
5.
Chinese Journal of Radiology ; (12)1999.
Artículo en Chino | WPRIM | ID: wpr-680111

RESUMEN

Objective To investigate the value of diffusion weighted imaging(DWI)in predicting delayed encephalopathy of the rabbits brain after carbon monoxide(CO)poisoning.Methods Sixty healthy rabbits were put into self-made poisoning cabinet and were poisoned by inhalation of CO.Aeration of CO was stopped when the rabbits became comatous,and the cabinet was kept airpoof for 6 h.The rabbits underwent MRI before poisoning,at 1 h,3 d,5 d,7 d,15 d,30 d,45 d,and 60 d after poisoning respectively. Axial and sagittal T_2WI,axial T_1WI and DWI were performed.In the rabbits that did not show symptoms of delayed encephalopathy,the observation was discontinued on the 60~(th)day.In the rabbit that showed the symptoms,the observation was discontinued on the 30~(th)——45~(th)day.The changing pattern of cortical ADC values before and after CO poisoning was observed and its relationship with delayed encephalopathy was investigated.Results In the group without delayed encephalopathy(15 rabbits),the ADC value at 1 h after poisoning[(7.58?0.36)?10~(-4)mm~2/s]decreased significantly compared with the pre-poisoning value[(8.02?0.35)?10~(-4)mm~2/s](q=0.4441,P0.05).In the group with delayed encephalopathy(15 rabbits),the ADC value at 1 h after poisoning [(7.40?0.32)?10~(-4)mm~2/s]decreased significantly compared with the pre-poisoning value[(8.08? 0.32)?10~(-4)mm~2/s](q=0.6728,P

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA